RFI APPROVED PRODUCTS
		
    			
    	        
        
		
					Latching
					
						Relay with 2 latched contact positions. The contacts change state with an electrical pulse supplied by one of the 2 power coils. To restore the starting position of the contacts, the other coil must be powered.
					
	
		
			 
					
						
							
								
									| Model | 
									Contacts | 
									Nominal   Current | 
									Coil input | 
									
									Note | 
									Classification | 
									 | 
								
							
						
							| OKBA | 
							
												 4
 
											 | 
							
												 10
 
											 | 
							DC or AC | 
							
							8 C/O as option | 
							Control relay, 4 C/O contacts, STF IFS TE 143A | 
							 | 
						
					
						
							| BAS8 | 
							
												 8
 
											 | 
							
												 10
 
											 | 
							DC or AC | 
							
							 | 
							Control relay, 8 C/O contacts, STF IFS TE 143A | 
							 | 
						
						
				
				
			
			
		 
	 
					Instantaneous, monostable
					
						The contacts change position instantaneously when the relay is powered and return instantaneously to their initial position when power is shut off.
					
	
		
			 
					
						
							
								
									| Model | 
									Contacts | 
									Nominal   Current | 
									Coil input | 
									
									Note | 
									Classification | 
									 | 
								
							
						
							| POKS | 
							
												 2
 
											 | 
							
												 10
 
											 | 
							DC or AC | 
							
							Compact, magnetic arc blow-out | 
							Control relay, Signal relay, 2 NO contacts, STF IFS TE 143A | 
							 | 
						
					
						
							| BIPOKS | 
							
												 4
 
											 | 
							
												 10
 
											 | 
							DC or AC | 
							
							Compact, magnetic arc blow-out | 
							Signal relay, 4 C/O contacts, STF IFS TE 143A | 
							 | 
						
					
						
							| TRIPOKS | 
							
												 6
 
											 | 
							
												 10
 
											 | 
							DC or AC | 
							
							Compact, magnetic arc blow-out | 
							Signal relay, 6 C/O contacts, STF IFS TE 143A | 
							 | 
						
					
						
							| OKSFC | 
							
												 4
 
											
												8
 
											
												12
 
											 | 
							
												 10
 
											 | 
							DC or AC | 
							
							8 and 12 C/O as option, 100.000.000 operations | 
							Control relay, 4 C/O contacts, STF IFS TE 143A | 
							 | 
						
						
				
				
			
			
		 
	 
					Time delayed, pick-up, drop-out, logic
					
						The contacts change status with time delay T with respect to the energization or de-energization of the relay input circuit. Logical function relays can be used for various functions, including CYCLIC, ONE-SHOT, etc.
					
	
		
			 
					
						
							
								
									| Model | 
									Contacts | 
									Nominal   Current | 
									Coil input | 
									
									Note | 
									Classification | 
									 | 
								
							
						
							| TM4E TMS4E | 
							
												 4
 
											 | 
							
												 5
 
											
												10
 
											 | 
							DC or AC | 
							
							Wide scale, Delay ON | 
							Signal relay, 4 C/O contacts, STF IFS TE 143A | 
							 | 
						
					
						
							| TM4R TMS4R | 
							
												 4
 
											 | 
							
												 5
 
											
												10
 
											 | 
							DC or AC | 
							
							Wide scale, Delay OFF | 
							Signal relay, 4 C/O contacts, STF IFS TE 143A | 
							 | 
						
					
						
							| OKTF | 
							
												 4
 
											 | 
							
												 10
 
											 | 
							DC or AC | 
							
							Delay OFF, no power supply | 
							Control relay, 2 C/O contacts, STF IFS TE 143A | 
							 | 
						
					
						
							| RMTZ04 | 
							
												 4
 
											 | 
							
												 10
 
											 | 
							DC | 
							
							RFI (Italian Railway) approved, T2 type relay | 
							T2 relay, timed, STF IFS TE 143A | 
							 | 
						
					
						
							| RMTZ05 | 
							
												 4
 
											 | 
							
												 10
 
											 | 
							DC | 
							
							RFI (Italian Railway) approved, T1 type relay | 
							T1 relay, timed, STF IFS TE 143A | 
							 | 
						
					
						
							| RMTZ07 | 
							
												 4
 
											 | 
							
												 10
 
											 | 
							DC | 
							
							RFI (Italian Railway) approved, T3 type relay | 
							T3 relay, timed, STF IFS TE 143A | 
							 | 
						
						
				
				
			
			
		 
	 
					Measurement
					
						The contacts change status for a defined input power value.
					
	
		
			 
					
						
							
								
									| Model | 
									Contacts | 
									Nominal   Current | 
									Coil input | 
									
									Note | 
									Classification | 
									 | 
								
							
						
							| MAMF12 | 
							
												 2
 
											 | 
							
												 10
 
											 | 
							DC | 
							
							Insulation between input and contact: 12kV | 
							Auxiliary relay, high insulation | 
							 | 
						
					
						
							| MAVF1X | 
							
												 2
 
											 | 
							
												 10
 
											 | 
							DC | 
							
							Measuring relay, insulation 15kV | 
							Voltage measuring relay, MIN/MAX thresholds, STF TE 155 | 
							 |